Specifications
J RATINGS/CHARACTERISTICS
Power supply voltage
12 VDC–10% to 24 VDC+15%, ripple (p-p) 5% max.
Current consumption
70 mA max.
Resolution (See Note 1)
256, 360, 720, 1,024 P/R
Output code (absolute)
Gray code
Output configuration
NPN open collector
Output capacity
Applied voltage
30 VDC max.
Isink
Residual voltage
35 mA max.
0.4 V max.
Max. response frequency (See Note 2)
20 kHz
Logic
Negative logic output (H=0, L=1)
Rotational direction
Clockwise, as viewed from the face of the shaft
Rise and fall times of output
Starting torque
1 µs max. (cable length: 2m; Isink: 35 mA max.)
100 gf S cm (0.087 in S lbf) max. at room temperature
150 gf S cm (0.13 in S lbf) max. at low temperature
Moment of inertia
15 g S cm2 (1.5 x 10–6 kg S m2) or 0.005 lb S in2 max.
Shaft loading
Radial
8 kgf (78.4N) or 17.6 lbf
Thrust
5 kgf (49N) or 11.0 lbf
Maximum permissible rotation
5,000 rpm
Ambient temperature
Operating
–10°C to 70°C (14°F to 158°F) with no icing
Storage
–25°C to 85°C (–13°F to 185°F) with no icing
Ambient humidity
Operating
35% to 85% (with no condensation)
Insulation resistance
20 Mmin. (at 100 VDC) between carry parts and case
Dielectric strength
Vibration resistance
Shock resistance
500 VAC, 50/60 Hz for 1 min between carry parts and case
Destruction: 10 to 500 Hz, 1.0-mm single amplitude or 150 m/s2 (approx. 15G) for 11
min. 3 times each in X, Y, and Z axes
Destruction: 1,000 m/s2 (approx. 100G) 3 times each in X, Y, and Z axes
Degree of protection
IEC IP64
Weight
300 g (0.66 lbs) with 2-m cable
Note: 1.
2.
A gray code signal with a remainder of 76 is used for a resolution of 360 per rotation and a gray code signal with a remainder of
152 is used for a resolution of 720 per rotation. Therefore, the code signal for a resolution of 360 per rotation uses addresses
76 through 435 and that for a resolution of 720 per rotation uses addresses 152 through 871.
The electrical maximum response rotation is determined by using the resolution and maximum response frequency in the fol-
lowing formula.
Electrical maximum response rotation (rpm) =
Maximum response frequency
Resolution
x 60
Therefore, a signal cannot follow electrically if the actual rotation exceeds the maximum response rotation.
2

विन्यास 10 पेज
डाउनलोड[ E6C2-A Datasheet.PDF ]


शेयर लिंक


अनुशंसा डेटापत्रक

भाग संख्याविवरणविनिर्माण
E6C2-AAbsolute Rotary EncoderOmron
Omron
E6C2-CIncremental Rotary EncoderOmron Electronics
Omron Electronics


भाग संख्याविवरणविनिर्माण
30L120CTSchottky RectifierPFC Device
PFC Device
AT28C010-12DKSpace 1-MBit (128K x 8) Paged Parallel EEPROMATMEL
ATMEL
B20NM50FDN-CHANNEL POWER MOSFETSTMicroelectronics
STMicroelectronics
D8442SD844SavantIC
SavantIC
FAE391-A20AM/FM Automotive Electronic TunerMitsumi
Mitsumi


Index : 0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z



www.DataSheet.in    |   2017   |  संपर्क   |   खोज     |   English