Technical Specification Bulletin Number
Fuel Type
Oil
Date of Issue
Jan 2005
Edition
1
TB137
www.datasheet4u.com
CI Oil Valve Adjustment
Page Number 2
The fuel enters via the filter and the float valve into the oil control itself. The rising oil level in the
oil control lifts the float and, as soon as the oil has reached the level mark, the float valve is closed
to allow only as much oil to flow into the control as flows out of it to the burner.
Adjustment of High and Low Fire Settings
When the stove is first put into operation, an adjustment of the oil control to the existing conditions,
sometimes proves necessary. Such adjustments are necessary if the minimum flue draught required
is not available or if the fuel oil used is not of the viscosity (cSt/25°C) specified on the name plate
of the oil control valve. Adjustment of the flow is only to be done when the heating device is in
operation.
After the flow has been corrected, 5 minutes must be allowed to elapse before the flame corresponds
to the newly adjusted flow. As a general rule, a quarter-turn of the flow adjustment screw suffices
to make the necessary correction. Alongside the flow adjustment screws are arrows indicating
which direction the screw must be turned to increase or decrease the flow.
The low fire screw has an arrow indicating low fire decrease as anticlockwise. This must only be
adjusted when the oil control valve is set at its minimum setting.
The high flame must first be adjusted with the stove running at maximum capacity. The high fire
screw has an arrow indicating high fire decrease as a clockwise turn of the screw.
Once the high fire has been adjusted the valve should be again turned to minimum setting and the
low fire setting re checked.
If the Valve has Flooded
Should the feed valve become leaky as a result of accumulated dirt, the oil level in the control rises
further, the over fill float rises releasing the arming lever and stopping any further oil entering the
control valve.
The appliance must be allowed to go cold before any work on the oil control valve or resetting of
the arming lever are attempted after the over fill float has been activated.
To re arm the valve the excess oil must be removed from the over fill chamber. This can be done
by first turning the oil control valve to the maximum setting and then pushing down the arming
lever and holding it down for 30 seconds. The burner pot will need the excess oil removing before
the burner is re lit.
Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom
Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100
Email tech@euroheat.co.uk Wed Site sales www.euroheat co.uk
Latest Technical Information www.euroheat.co.uk/support

विन्यास 4 पेज
डाउनलोड[ TB137 Datasheet.PDF ]


शेयर लिंक


अनुशंसा डेटापत्रक

भाग संख्याविवरणविनिर्माण
TB1300HSURFACE MOUNT THYRISTOR SURGE PROTECTIVE DEVICELite-On
Lite-On
TB1300H(TB0640H - TB3500H) BI-DIRECTIONAL SURFACE MOUNT THYRISTOR SURGE PROTECTIVE DEVICEDiodes Incorporated
Diodes Incorporated


भाग संख्याविवरणविनिर्माण
30L120CTSchottky RectifierPFC Device
PFC Device
AT28C010-12DKSpace 1-MBit (128K x 8) Paged Parallel EEPROMATMEL
ATMEL
B20NM50FDN-CHANNEL POWER MOSFETSTMicroelectronics
STMicroelectronics
D8442SD844SavantIC
SavantIC
FAE391-A20AM/FM Automotive Electronic TunerMitsumi
Mitsumi


Index : 0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z



www.DataSheet.in    |   2017   |  संपर्क   |   खोज     |   English