DataSheet.in

GPR323916A डेटा पत्रक PDF( Datasheet डाउनलोड )


डेटा पत्रक - Synchronous DRAM - Generalplus

भाग संख्या GPR323916A
समारोह Synchronous DRAM
मैन्युफैक्चरर्स Generalplus 
लोगो Generalplus लोगो 
पूर्व दर्शन
1 Page
		
<?=GPR323916A?> डेटा पत्रक पीडीएफ

GPR323916A pdf
GPR323916A
Table of Contents
PAGE
1. GENERAL DESCRIPTION .......................................................................................................................................................................... 4
2. FEATURES .................................................................................................................................................................................................. 4
3. BLOCK DIAGRAM ...................................................................................................................................................................................... 5
4. PIN DESCRIPTIONS ................................................................................................................................................................................... 6
4.1. PIN ASSIGNMENT (TSOP II TOP VIEW).................................................................................................................................................... 7
5. OPERATION MODE .................................................................................................................................................................................... 8
6. COMMANDS ............................................................................................................................................................................................... 9
6.1. BANKACTIVATE (RAS# = "L", CAS# = "H", WE# = "H", BSS = BANK, A0-A11 = ROW ADDRESS).............................................................. 9
6.2. BANKPRECHARGE COMMAND (RAS# = "L", CAS# = "H", WE# = "L", BSS = BANK, A10 = "L", A0-A9 AND A11 = DON'T CARE).................. 9
6.3. PRECHARGEALL COMMAND (RAS# = "L", CAS# = "H", WE# = "L", BSS = DONT CARE, A10 = "H", A0-A9 AND A11 = DON'T CARE) .......... 9
6.4. READ COMMAND (RAS# = "H", CAS# = "L", WE# = "H", BSS = BANK, A10 = "L", A0-A8 = COLUMN ADDRESS) ....................................... 9
6.5. READ AND AUTOPRECHARGE COMMAND (RAS# = "H", CAS# = "L", WE# = "H", BSS = BANK, A10 = "H", A0-A8 = COLUMN ADDRESS) .. 10
6.6. WRITE COMMAND (RAS# = "H", CAS# = "L", WE# = "L", BSS = BANK, A10 = "L", A0-A8 = COLUMN ADDRESS)..................................... 10
6.7. WRITE AND AUTOPRECHARGE COMMAND (RAS# = "H", CAS# = "L", WE# = "L", BSS = BANK, A10 = "H", A0-A8 = COLUMN ADDRESS) ..11
6.8. MODE REGISTER SET COMMAND (RAS# = "L", CAS# = "L", WE# = "L", A0-A11 = REGISTER DATA) .......................................................11
6.8.1. Burst Length Field (A2~A0)..................................................................................................................................................... 12
6.8.2. Burst Type Field (A3) .............................................................................................................................................................. 12
6.8.3. Burst Definition, Addressing Sequence of Sequential and Interleave Mode........................................................................... 12
6.8.4. CAS# Latency Field (A6~A4) .................................................................................................................................................. 12
6.8.5. Test Mode Field (A8~A7) ........................................................................................................................................................ 12
6.8.6. Write Burst Length (A9)........................................................................................................................................................... 13
6.9. NO-OPERATION COMMAND (RAS# = "H", CAS# = "H", WE# = "H")....................................................................................................... 13
6.10.BURST STOP COMMAND (RAS# = "H", CAS# = "H", WE# = "L")............................................................................................................ 13
6.11. DEVICE DESELECT COMMAND (CS# = "H") ........................................................................................................................................... 13
6.12.AUTOREFRESH COMMAND(RAS# = "L", CAS# = "L", WE# = "H",CKE = "H", A11 = “DONT CARE, A0-A9 = DON'T CARE)....................... 13
6.13.SELFREFRESH ENTRY COMMAND(RAS# = "L", CAS# = "L", WE# = "H", CKE = "L", A0-A9 = DON'T CARE) ........................................... 13
6.14.SELFREFRESH EXIT COMMAND ............................................................................................................................................................ 13
6.15.CLOCK SUSPEND MODE ENTRY / POWERDOWN MODE ENTRY COMMAND (CKE = "L") ........................................................................... 13
6.16.CLOCK SUSPEND MODE EXIT / POWERDOWN MODE EXIT COMMAND (CKE= "H").................................................................................. 14
6.17.DATA WRITE / OUTPUT ENABLE, DATA MASK / OUTPUT DISABLE COMMAND (DQM = "L", "H")................................................................. 14
7. ELECTRICAL SPECIFICATIONS ............................................................................................................................................................. 15
7.1. ABSOLUTE MAXIMUM RATING ............................................................................................................................................................... 15
7.2. RECOMMENDED D.C. OPERATING CONDITIONS (TA = - 0~70) ............................................................................................................ 15
7.3. CAPACITANCE (VDD = 3.3V, F = 1MHZ, TA = 25)............................................................................................................................... 15
7.4. RECOMMENDED D.C. OPERATING CONDITIONS (VDD = 3.3V ± 0.3V, TA = 0~70) ............................................................................... 15
7.5. ELECTRICAL CHARACTERISTICS AND RECOMMENDED A.C. OPERATING CONDITIONS (VDD = 3.3V±0.3V, TA = 0~70) (NOTE: 5, 6, 7, 8)16
8. TIMING WAVEFORMS .............................................................................................................................................................................. 18
8.1. AC PARAMETERS FOR WRITE TIMING (BURST LENGTH=4)..................................................................................................................... 18
8.2. AC PARAMETERS FOR READ TIMING (BURST LENGTH=2, CAS# LATENCY=2) ........................................................................................ 19
8.3. AUTO REFRESH (CBR) (BURST LENGTH=4, CAS# LATENCY=2)............................................................................................................ 20
8.4. POWER ON SEQUENCE AND AUTO REFRESH (CBR) .............................................................................................................................. 21
8.5. SELF REFRESH ENTRY & EXIT CYCLE................................................................................................................................................... 22
© Generalplus Technology Inc.
Proprietary & Confidential
2
Mar. 30, 2009
Version: 1.0

विन्यास 30 पेज
डाउनलोड[ GPR323916A Datasheet.PDF ]


शेयर लिंक


अनुशंसा डेटापत्रक

भाग संख्याविवरणविनिर्माण
GPR323916ASynchronous DRAMGeneralplus
Generalplus


भाग संख्याविवरणविनिर्माण
30L120CTSchottky RectifierPFC Device
PFC Device
AT28C010-12DKSpace 1-MBit (128K x 8) Paged Parallel EEPROMATMEL
ATMEL
B20NM50FDN-CHANNEL POWER MOSFETSTMicroelectronics
STMicroelectronics
D8442SD844SavantIC
SavantIC
FAE391-A20AM/FM Automotive Electronic TunerMitsumi
Mitsumi


Index : 0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F  G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z



www.DataSheet.in    |   2017   |  संपर्क   |   खोज     |   English